1-channel transmitter
Liquiline Compact CM72
Single-parameter field device for hazardous and non-hazardous applications in all industries
The Liquiline Compact CM72 is a small transmitter for Memosens sensors. It is the right choice for you if installation space is limited and you don't need the flexibility of a multiparameter device. Together with the sensor, it fits into most assemblies and couldn't be easier to install. The measuring parameter and measuring range are already defined during the ordering process, making the CM72 immediately ready for use with a high degree of safety against operating errors.
-
Benefits
Space-saving installation:
The two-wire device fits inside an assembly and does not require its own power supply.Fast start-up:
Thanks to its fixed configuration, the CM72 does not have to be commissioned and can quickly start its work.Benefit from all...
-
Field of application
Liquiline Compact CM72 can be used in all industries and their utilities and supports all sensors with the blue Memosens plug-in head:
pH sensors
ORP sensors
Conductivity sensors
Oxygen sensors
Chlorine sensors
The measurement parameter and range are...
Documents / Manuals / Software
-
Liquiline Compact CM72
Technical Information
Permanently preconfigured single-parameter transmitter for Memosens
sensorsTechnical Information (TI) -
Liquiline Compact CM72
Operating Instructions
Space-saving compact transmitter for monitoring and controlling
processes in industry and the environmental sectorOperating Instruction (BA) -
Junction Box
Operating Instructions
Junction Box
Operating Instruction (BA) -
Liquiline Compact CM72
Brief Operating Instructions
Liquiline Compact CM72
Short Instruction (KA)04/18German , English , fr -
Einzelparameter Messumformer CM72
1-Kanal Einzelparameter-Messumformer für die Analyse-Messtechnik
zur Überwachung und Steuerung von verfahrenstechnischen Prozessen. Mit
dem 2-
Draht-
MessumformerTender Text06/19German -
Liquiline M
Product Code: CM72-
Declaration Number: EC_00673_01.18EU DeclarationGerman , English , fr -
Liquiline M
Product Code: CM72-
Declaration Number: EC_00583_02.17EU DeclarationGerman , English , fr -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Product Code: CPS491-, CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91D-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CPS16D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Approval Number: EAEC RU D-DE.AD07.B.01362/19MiscellaneousRussian -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Product Code: CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS16D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Region/Country: Russia (Declaration of Conformity)
Approval Number: EAEC D-DE.AD07.B.01363/19MiscellaneousRussian -
Liquiline
Product Code: CM72-, CM82-
Region/Country: Canada
Approval Agency: CSAOrdinary Location Product SafetyEnglish -
Liquiline, Liquiline M
Product Code: CM72-, CM82-
Ordinary Location Product SafetyEnglish
Accessories / Spare parts
-
-
Order code DIENST-F
Marking Tagging (Attention: select option and enter text in 995)
-
Order code CYP02D-
Memocheck CYP02D
-
Order code CYP03D-
Memocheck Sim CYP03D
Hand held; continous measurement value simulation. Simulation of digital sensors;Memosens;all parameters Memosens sensors; inductive coupling fixed cable sensors; Memosens protocol Check of relays and control functions Complete loop check
-
Order code RIA15-
Loop Powered Process Indicator RIA15
Without power supply, 1 channel, scalable, loop powered, display LC 5-digit, optional with HART communication, optionally backlit. Bargraph resolution 10% over/underrange.
-