                  Specs at a glance
- 
                              Max. process pressure (static)40 bar (580 psi) 
- 
                              Maximum standard immersion length48" (1.219 mm) 
Field of application
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular re-calibration by simply replacing the insert in closed processes.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
- Pressure range up to 40 bar (580 psi) 
- For increased protection requirements of the temperature sensor regarding physical and chemical effects 
- For use in pipes and containers or tanks 
- Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes 
Benefits
-  iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration of the insert used 
-  All common hygienic process connections 
-  International certification: hygiene standards as per 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability 
-  Fast response time owing to reduced tips with thin walls 
-  State of the art Tee and Elbow thermowells, without welds and dead legs and with best in class hygienic design 
Extended selection
- 
        High-end products 
- Highly functional and convenient
Technical excellence
Simplicity
 
                              - 
        Standard products 
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
- 
        Specialized products 
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity | 
|---|---|---|
| 
 Fundamental selection Meet your basic measurement needs | Technical excellence | Simplicity | 
| 
 Lean selection Handle your core processes easily | Technical excellence | Simplicity | 
| 
 Extended selection Optimize your processes with innovative technologies | Technical excellence | Simplicity | 
| 
 Xpert selection Master your most challenging applications | Technical excellence | Simplicity Variable | 
Predecessor
- 
                        - 
                                                            Technical Information (TI)
 TI Weld-in adapter, process adapter and flangesLevel, pressure and temperature measurement EN 06/12/202425/03/202415/09/202328/10/202130/07/2021Language: English Version: 06/12/2024 File size: 1.3 MB File name: TI00426FEN_2624.pdf 
- 
                                                            
- 
                        - 
                                                            Technical Information (TI)
 TI iTHERM ModuLine TT412 Welded thermowellImperial thermowell for hygienic and aseptic applications in the food, beverage, and pharmaceutical industries EN 31/08/202529/07/202213/01/202131/10/201804/08/2017Language: English Version: 31/08/2025 File size: 1.2 MB File name: TI01350TEN_0525-00.pdf 
- 
                                                            
- 
                        - 
                                                            Special Documentation (SD)
 Device viewerTechnical documentation in other languages Language: English Version: 14/07/2021 File size: 478.5 KB File name: SD02429R09EN_0121.pdf 
- 
                                                            
- 
                        - 
                                                            Special Documentation (SD)
 SD Hygienic process connection typesSupplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411, 
 TT412, TE411, TK40, TMR35, DTT35, TTR35Language: English Version: 15/09/2023 File size: 800.3 KB File name: SD03119TEN_0123-00.pdf 
- 
                                                            
- 
                        - 
                                                            Manufacturer Declaration
 Product family: Accessories: Pipe thermowell, Accessories: Inserts, PROCESS RTD HYGIENIC, RTD thermometerProduct root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, 
 TM412-, TMR35-, TS111-, TS212-, TT411-, TT412-
 Declaration number: HE_00886_01.17
 Additional information: TSE compliance, animal fat freeEN 23/10/2017Language: English Version: 23/10/2017 File size: 160.7 KB File name: HE_00886_0117.pdf 
- 
                                                            
- 
                        - 
                                                            Manufacturer Declaration
 Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometerProduct root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- 
 Declaration number: HE_01097_03.24
 Manufacturer specification: Food hygieneLanguage: English Version: 24/10/2024 File size: 112.3 KB File name: HE_01097_03.24_en.pdf 
- 
                                                            
- 
                        - 
                                                            Manufacturer Declaration
 Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometerProduct root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- 
 Declaration number: HE_00099_05.15
 Manufacturer specification: Food hygiene, 10/2011, 1935/2004EN 07/12/2020Language: English Version: 07/12/2020 File size: 1.7 MB File name: HE_00099_05.15.pdf 
- 
                                                            
- 
                        - 
                                                            Manufacturer Declaration
 Product family: Process RTD hygienicProduct root: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-, 
 TS112-, TT411-, TT412-
 Declaration number: MD-12028A-9Language: English Version: 10/01/2013 File size: 872.7 KB File name: MD-12028a_09_e.pdf 
- 
                                                            
- 
                        - 
                                                            Manufacturer Declaration
 Product family: Accessories: Bar stock thermowell, Accessories: Pipe thermowell, Accessories: Inserts, Magphant, Process RTD general purpose, Process RTD hygienic, RTD thermometerProduct root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, 
 TS111-, TS212-, TT131-, TT151-, TT411-, TT412-
 Declaration number: HE_01494_01.21
 Manufacturer specification: Food hygiene
 Additional information: BSE, TSELanguage: English Version: 27/07/2023 File size: 266 KB File name: HE_00886_07_17.pdf 
- 
                                                            
- 
                        - 
                                                            FDA Declaration
 Product family: Accessories: Pipe thermowell, Process RTD hygienic, RTD thermometerProduct root: TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TT411-, TT412- 
 Declaration number: FDA_00127_04.25EN 20/07/2025Language: English Version: 20/07/2025 File size: 422.5 KB File name: FDA_00127_04.25.pdf 
- 
                                                            
 
                                             
                                             
                                             
                                             
                                             
                                     
                                     
                                     
                                    