Specs at a glance
-
Input
2...8x PFM
2...8x I
2...8x Impulse (aktiv)
2...6x RTD
2...8x Impulse (passiv) -
Output
3...9x transmitter power supply
-
Display
LC-Dot-Matrix 160 x 80 Punkte
-
Calculations
mass/heat quantity
heat quantity difference
for gases: standard volume, heating value, mass
Field of application
The flow and energy manager RMC621 calculates standard volume as well as mass and energy flows of natural and technical gases, fluids and steam from flow, pressure, temperature and density. Depending on the medium calculation of the energy values occurs according to international standards (IAPWSIF97, SGERG88), real gas equations (SRK) or specific tables. For differential pressure measurements coefficients for flow compensation are calculated over the complete operating range of the flow sensor.
Energy management
Chemical industry
Heating and air conditioning
Pharmaceutical industry
Food and beverage
Plant and panel manufacture
Oil + petrochemicals
Benefits
Suitable for applications with gas, liquid, steam and water
Simultaneous calculation of up to 3 measuring applications, even if different fluids are used
Very precise process calculations (density, enthalpy, compressibility) on the basis of equations and/or storable tables with material data
Calculation standards: IAPWS-IF 97, SGERG88, AGA8, real gas equations (SRK, RK), ISO 5167, tables
Can be used with all common flow measuring systems (vortex, turbine, MID, orifice plate, differential pressure, etc.)
Compensation input for density signal
Logbook function for error messages and parameter changes with date and time
Predecessor
-
-
Technical Information (TI)
RMC621 Technical Information
Universal flow and energy computer for gases, liquids and steam
EN 23/11/201713/02/201731/08/201004/02/200813/07/2006Language:
English
Version:
23/11/2017
File size:
921.7 KB
File name:
TI00098REN_1517.pdf
-
-
-
Operating Instruction (BA)
RMx621 / FML621
PROFINET module ("PROFINET coupler") from V3.03.01
EN 28/02/2020Language:
English
Version:
28/02/2020
File size:
5.2 MB
File name:
BA02024REN_0120.pdf
-
-
-
Operating Instruction (BA)
RMx621 Operating Instructions
Appendix to the Operating Instructions M-Bus interface V3.08.00: Connecting the Energy Manager to M-Bus system (two-wire bus in acco rdance with DIN EN 1434-3)
EN 01/03/201715/08/201120/01/201128/11/200820/09/2007Language:
English
Version:
01/03/2017
File size:
259.5 KB
File name:
BA00216REN_0317.pdf
-
-
-
Operating Instruction (BA)
Zusatzbetriebsanleitung/Addition Manuals Ethernet-Anbindung
Zusatzbetriebsanleitung/Addition Manuals Ethernet-Anbindung Memo-/Eco-Graph
EN 09/05/200805/07/2004Language:
English
Version:
09/05/2008
File size:
155.8 KB
File name:
ZBA109Ra2_0408.pdf
-
-
-
Operating Instruction (BA)
Supplement to Operating Instructions RMC621
Ergänzung zur Betriebsanleitung Energiemanager RMC621 / Supplement to Operating Instructions Energy Manager RMC621
EN 14/12/2006Language:
English
Version:
14/12/2006
File size:
657.5 KB
File name:
BA249Rd5.pdf
-
-
-
Operating Instruction (BA)
Operating instructions Flow and energy manager RMC 621
Flow and Energy manager RMC 621, universal flow and energy computer for gases, liquids and steam
EN 14/02/2017Language:
Finnish
Version:
14/02/2017
File size:
3 MB
File name:
BA00144RFI_1517.pdf
-
-
-
Operating Instruction (BA)
RMx621 / FML621
DP slave module ("PROFIBUS coupler") from V2.01.00
EN 03/02/2020Language:
English
Version:
03/02/2020
File size:
683.7 KB
File name:
BA00154REN_1320.pdf
-
-
-
Operating Instruction (BA)
Appendix to operating instructions RMx621
Energy Manager and Application Manager RMx621 with ModBus Interface V3.03.00. Connecting the Energy/Application Manager to ModBus-IDA-systems
EN 11/08/200928/11/200820/09/200705/05/2006Language:
English
Version:
11/08/2009
File size:
449.7 KB
File name:
Ba231ren_0809.pdf
-
-
-
Operating Instruction (BA)
Operating Manuals ReadWin 2000 (GB)
Operating Manuals ReadWin 2000
EN 01/01/201031/10/200820/06/200725/07/2001Language:
English
Version:
01/01/2010
File size:
6.3 MB
File name:
BA137Ren_0110.pdf
-
-
-
Short Instruction (KA)
Brief Operating Instructions RMC621, RMS621
RMC621: Flow and Energy Manager RMS621: Energy Manager
EN 06/11/2017Language:
English
Version:
06/11/2017
File size:
1.1 MB
File name:
KA01321K09EN_0117.pdf
-